Instructions forXL-45HP, XL-50HP, XL-55HP and XL-50VHPwith Dual RegulatorDo not attempt to use or maintain thisunit until you read and understand thes
Pressure Transfer Filling Procedure (Low Pressure Source) - Once you have deter-mined the proper full weight for a container, connect a transfer hose
In use, the CGA Tailpiece couples to the fill connection on the container being filled. TheRelief Valve vents pressure over 350 psig (24 bar/2413 kPa)
VENT TEE CHARTThe vent tee chart connects to a transfer hose to complete a fill line kit. Each assemblyincludes a 3/8 in. pipe connector to CGA fittin
GAS SERVICE CHANGE KITSKit Valve ConnectionPart No. Gas Service Name DesignationGL50-8C35 Oxygen LIQUID CGA 440VENT CGA 440USE CGA 540GL50-8C30 Nitrog
Regulator Removal or Replacement Procedure1. Close manual Pressure Building valve.2. Vent the container to atmospheric pressure. 23. Loosen and remove
CHECKING CONTAINER PERFORMANCECryogenic containers are two containers, one within the other. The space between thecontainers acts as a highly effici
FULL VIEW CONTENTS GAUGE MAINTENANCEThe content of these containers is measured with the Full View Contents Gauge. Thedevice consists of the gauge
Contents Gauge InstallationBefore installing a new or repaired gauge, inspect the gasket seals. If any damage isapparent, replace the gasket. (See fol
6. When you are satisfied that the float rod is correctly installed, lower the assembly therest of the way into the container until the top portion th
HAND VALVE REPAIRHand valves are an integral part of the container, and the valve bodies rarely need replace-ment. However, the handwheel and the inte
Pressure Hazard The containers covered by this literature may contain pressures up to350 psig (24 bar/2413 kPa) for the XL-45HP/50HP/55HP and pressu
Valve Replacement Instructions1. Partially thread Seat Assembly (12) (seat disc first) into large end of Bushing (13)leaving tang of nipple assembly e
SHOCK MOUNT FOOT RINGItem No. Description Part No. (XL-55 Only) Qty.1 Rubber Shock Ring XL50-4C18 (GL55-4C21) 12 Foot Ring XL50-4C19 (GL55-4C19) 13 He
The following chart is provided to give you some guidance in determining the probablecause and suggested corrective action for some problems that may
TROUBLESHOOTINGSymptom Possible Cause Corrective ActionContainer is cold and 1. Vacuum loss. Check NER. 1. Consult with Taylor-Whartonmay have ice or
This replacement part list include a recommended inventory quantity which allows you toorder part on a timely basis to keep all your XL-45/50/55 conta
Index RecommendedNo. Description Part No. For 10 Units1. Dual Regulator, Pressure Building/Economizer 8816-1060 2 Each400 psig (28 bar/2758 kPa) - for
Index RecommendedNo. Description Part No. For 10 Units17.- VENT (CGA 440) - oxygen 6514-8992 5 Each- VENT (CGA 295) - argon/nitrogen 7355-4712 5 Each-
SPECIFICATIONSXL-45HP XL-50HP XL-55HP XL-50VHPDimensionsDiameter 20 in. (508 mm) 20 in. (508 mm) 20 in. (508 mm) 20 in. (508 mm)Height 61 3/8 in. (155
Handling the ContainerThe XL Series containers are very rugged liquid cylinders. All cryogenic liquid containershave an inner container and an outer c
The XL-45HP will store up to 165 liters of product; the XL 50HP/50VHP up to 176 liters,and 196 liters for the XL-55HP. All four cylinders can deliver
inner container is vaporized in a heat exchanger which is insidethe outer casing. The expanding gas is fed into the upper sec-tion of the container to
The PRESSURE BUILDING Valve This valve isolates the liquid in the bottom of thecontainer to the Dual Pressure Building/Economizer Regulator. This va
WITHDRAWING GAS FROM THE CONTAINERTo withdraw gas from the XL-45HP/50HP/55HP/50VHP connect a suitable pressure regu-lator to the USE connection, a
FILLING THE CONTAINERCryogenic liquid containers must always be filled by weight to ensure there is enough gashead space (ullage) for liquid to expa