Taylor-wharton XL-240 Manuel d'utilisateur Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 18
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
Lower the assembly about 4 in. (102 mm) slowly and try to keep the rod in the center of
the threaded entrance hole as you do. If you are careful during this portion of the inser-
tion, you will drop the float rod straight though the guide ring inside the cylinder.
1. To confirm that the rod is correctly positioned in the cylinder, stop where you can
still grasp the top of the rod (see illustration) and try to swing the lower end from
side to side.
2. When the rod is engaged in the guide ring, the rod will be restricted to lower end
movement of about ½ in. (12.7 mm); if you can feel greater movement, withdraw
the rod to the point where its top is 8 in. (203 mm) above the gauge opening and try
again.
3. When you are satisfied that the float rod is correctly installed, lower the rest of the
way into the container until the top portion threads can be engaged.
4. Screw the gauge in place and hand torque to about 20 ft. lbf (2.8 kgf m). Leak check
the connection of gauge body to the flange.
CAUTION:
When installing the gauge assem-
bly, care must be taken to ensure
that the float rod is inserted through
“guide ring” located on the liquid
withdrawal line inside container. IF
gauge does not engage this ring, the
contents indication will be inaccu-
rate, or the gauge may be damaged
in use.
Contents Gauge Insertion
Vue de la page 13
1 2 ... 9 10 11 12 13 14 15 16 17 18