Vue de la page 0
Instructions For
XL-45, XL-50 and XL-55
with Dual Regulator
Instructions for
XL-45, XL-50 and XL-55
with Dual Regulator
Do not attempt to use or maintain this
unit until you read and understand these
instructions. Do not permit untrained
persons to use or maintain this unit. If
you do not fully understand these
instructions, contact your supplier for
further information.
TW-287
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - XL-45, XL-50 and XL-55

Instructions ForXL-45, XL-50 and XL-55with Dual RegulatorInstructions forXL-45, XL-50 and XL-55with Dual RegulatorDo not attempt to use or maintain th

Page 2 - INFORMATION

2. During the fill, monitor the container pressure and maintain a pressure of 10-15 psig(0.7-1 bar/69-103 kPa) by throtting the VENT valve.3. When the

Page 3 - SPECIFICATIONS

Fill kits are available with different combinations of hose length and fittings for a specificgas service. The following chart identifies the availabl

Page 4 - Containers

Service CGA Connection Part NumberInert (N2, Ar) CGA 295 GL50-8C60Read the Safety Precautions in the front of this manual before attempting any repair

Page 5 - OPERATION

GAS SERVICE CHANGE KITSKit Valve ConnectionPart No. Gas Service Name DesignationGL50-8C35 Oxygen LIQUID CGA 440VENT CGA 440USE CGA 540GL50-8C30 Nitrog

Page 6 - Flow Diagram

Regulator Removal or Replacement Procedure1. Close manual Pressure Building Valve.2. Vent the container to atmospheric pressure.3. Loosen and remove b

Page 7 - Building Rates

CHECKING CONTAINER PERFORMANCECryogenic containers are two container, one within the other. The space between thecontainers acts as a highly efficient

Page 8 - Withdrawal

Wharton Customer Service at (334)443-8680 for disposition.FULL VIEW CONTENTS GAUGE MAINTENANCEThe content of these containers is measured with the Ful

Page 9

Contents Gauge InstallationBefore installing a new or repaired gauge, inspect the gasket seals. If any damage isapparent, replace the gasket. (See fol

Page 10

again.6. When you are satisfied that the float rod is correctly installed, lower the assembly therest of the way into the container until the top port

Page 11 - Fill Hose Kits

HAND VALVE REPAIRHand valve are an integral part of the container, and the valve bodies rarely need re-placement. However, the handwheel and internal

Page 12 - PROCEDURES

NOTE:For detailedinformation on thehandling of cryogenicliquids, refer to theCompressed GasAssociationpublication: P-12“Safe Handling ofCryogenic Liqu

Page 13

residue and foreign particles.Valve Replacement Instructions1. Partially thread Seat Assembly (12) (seat disc first) into large end of Bushing (13)lea

Page 14 - Adjustment

SHOCK MOUNT FOOT RINGItem No. Description Part No. (XL-55 Only) Qty.1 Rubber Shock Ring XL50-4C18 (GL55-4C21) 12 Foot Ring XL50-4C19 (GL55-4C19) 13 He

Page 15

then inspect your work.The following chart is provided to give you some guidance in determining the probablecause and suggested corrective action for

Page 16 - Full View Contents

TROUBLESHOOTING CHARTSymptom Possible Cause Corrective ActionContainer is cold and 1. Vacuum loss. Check NER. 1. Consult with Taylor-Whartonmay have i

Page 17 - XL-45, XL-50, XL-55

This replacement part list include a recommended inventory quantity which allows you toorder part on a timely basis to keep all your XL-45/50/55 conta

Page 18 - Insertion

Index RecommendedNo. Description Part No. For 10 Units1. Dual Regulator, Pressure Building/Economizer 69999-9015 2 Each125 psig (8.6 bar/862 kPa)* 2.

Page 19 - HAND VALVE REPAIR

XL-45 XL-50 XL-55DimensionsDiameter 20 in. (508 mm) 20 in. (508 mm) 20 in. (508 mm)Height 61 ½ in. (1562 mm) 64 5/8 in. (1641 mm) 69 7/8 in. (1764 mm)

Page 20

Handling the ContainerThe XL Series containers are very rugged liquid cylinders. All cryogenic liquid cylindershave an inner container and an outer co

Page 21 - Exploded View

The XL-45 will store up to 169 liters of product, the XL-50 up to 181 liters and 200 litersfor the XL-55. All three cylinders can deliver either liqui

Page 22 - TROUBLESHOOTING

inner container is vaporized in a heat exchanger whichis inside the outer casing. The expanding gas is fed intothe upper section of the container to b

Page 23

The VENT Valve – This valve controls a line into the head space of the container. It isused during the fill process. The VENT valve acts as a fill poi

Page 24 - ACCESSORIES

Increasing Gas Supply Capacity – Two or more liquid containers may be manifoldedtogether. Accessory manifolds are available for use in creating a high

Page 25 - ° 6814-9241 2 Each

Determine Proper Fill Weight1. Visually inspect the container. Do not attempt to fill containers with broken or missingcomponents.2. Move the containe

Modèles reliés XL-50 | XL-45 |